4" Bulk Head was installed in pond wall. 4" pipe was plumbed to a Retro Drain [Waite of the drain holds down the Retro Drain.
4" Pipe to 45 degree Elbow thru Filter Building wall into a 4" Gate Knife ...to a 4" T....Where we installed a reducer to 2" to add a 2" Ball Valve for Air release incase there was a air lock in the pipe after the 4" Bulkhead.
We 90 degree Elbow to the flow of the building and 45 degree to the out side of the building. |
|
 |
Lower 4" Plumbing goes directly to the Ceus Sieve.
Upper 4" Plumbing goes from the Cetus Sieve to the 1/2 H.P. Artesian Pro Pump back to the Water Fall.
2" Plumbing belongs to the Challenger 60 Filter and EP 10 UV Light. |
|
 |
4" Pipe runs out of the filter building to a 90 degree elbow that runs down to the floor of the fliter area.....to a 90 degree elbow ....to a 4" "T"... to another 90 degree elbow to run a 4" pipe along side the Cetus Sieve to it's front [This pipe is placed there to help take away air locks from the system..
Out fromt from the 4" T leading right into the Boot of the Cetus Sieve InPut. |
|
|
 |
4" Pipe that runs between the Cetus and Nexus is plumbed to the straight end of the 4" "T" .
The other side of the Straight side of the "T" is plumbed to the Sequence 750 pumps Out Put.....1 1/2" Pump increased to 2" pipe to be plumbed to the OutPut of the Cetus Sieves 2". NOTICE we installed an Air Release Valve in the 4" 90 degree Elbow to release air from the pipe.
Note: 3" boot from the front
The Upper Part of the "T" is plumbed into the InPut of the Nexus Filter.
Flow: Water from Pond to Back of Cetus and air bypass 4"....from the Cetus Input from Pond to the Cetus to the Sequence 750 pump...From the Sequence 750 Pump to the Nexus Filter. |
|
 |
Out Put for the Nexus has a 2" boot with Pipe Bands. 2" Pipe is plumbed from the 2" boot of the Out Put of the Nexus to the front of the Artesian 1/4 H.P. Pump. A Ball Valve is installed before the Input of the pump in case we need to shut the water off to take the pump out for serviceing the pump.
Out put of the pump is 2" with a 2" Ball Value installed just after the Output of the pump incase the water flow needs to be adjusted to keep the right level of water in the Nexus.An Adapter is placed in the 2" to increased to 4" pipe to run to the water fall. |
|
 |
We Installed a Sump Pump in the lower part of the filter areas.
We dug down low enough for a 5 gallon bucked to be placed in the ground upside down. We cut out the bottom of the bucket and added gravel.
We placed the sump pump in the bucket.
We plumbed the out put to the drainage pipe that led to the other side of the yard to water the grass and flower garden. |
|
 |
We install a water line to attach to a garden hose. On the end of the Garden hose a Spray Nozzle was attached to help in cleaning the Cetus Sieves Screen. |
|
|

We placed a shelf for the Two Air pumps. One Runs the Nexus and the other Air pump runs the Eazy Pod Filter and Show tank.
Steps lead down into the filter area.
There are 4 drains in the floor of the area which have pea gravel under the cement for drainage.
|